Required Equipment per NFPA 1901 |
|
Water Tank, min 1000 gal. |
|
20 cubic feet of compartments for equipment storage. |
|
Hose Storage |
|
One area, min 6 cu. ft. for 2 1/2" or larger hose |
|
Two areas, each 3.5 cu ft for 1 1/2" or larger preconnected
hose. (if equipped with a pump) |
|
1200ft of 2 1/2" or larger fire hose |
|
If there is a pump, a minimum of 15ft of soft suction or 20ft of
hard suction hose shall be carried. |
|
400ft of 1 1/2", 1 3/4", or 2" hose |
|
Two combination fog nozzles, 95gpm minimum |
|
One 6lb flathead or pickhead axe |
|
One 6ft pike pole or plaster hook |
|
Two portable hand lights w/ mounting brackets |
|
One dry chemical portable fire extinguisher w/ minimum 80-BC rating |
|
One 2 1/2 gallon water extinguisher |
|
One SCBA complying with NFPA 1981 for each assigned seating
position, but not less than two. |
|
One spare SCBA cylinder for each SCBA carried. |
|
One first aid kit |
|
Two combination spanner wrenches with brackets |
|
One hydrant wrench |
|
One double female adapters, sized to fit 2 1/2" or larger hose. |
|
One double male adapters, sized to fit 2 1/2" or larger hose. |
|
One rubber mallet if equipped with a pump |
|
Two wheel chock |
|
|
|
Recommended Equipment per NFPA 1901 |
|
One fire service claw tool |
|
One crowbar |
|
One pair insulated bolt cutters |
|
One Halligan-type tool |
|
One 2 1/2" hydrant valve |
|
One double-gated reducing leader wye |
|
Two shovels, pointed |
|
Four hose straps |
|
One 125ft length of utility rope (5000lb breaking strength minimum) |
|
One portable pump |
|
One level strainer |
|
Toolbox with assorted tools |
|
One 1500gal minimum collapsable, portable tank |
|
One water transfer device to be used between portable tanks |